Amerway, Inc.
                                                                                         Quality Through People and Technology

Amerway #70 Water Soluble Flux


Material Safety Data Sheet

Section 01 Identification
Information furnished by: Amerway, Inc.
3701 Beale Avenue
Altoona, PA 16601
Date effective: 1/1/08
Emergency phone: 1-814-944-0200
Chemtrec: 1-800-424-9300
Product or trade name: Amerway Plumbing Flux # 70
Product Use: Soldering flux
Person to contact: Terry Buck
Section 02 Constituents      
Chem CAS %Wt PEL/PPM TLV/PPM
Zinc Chloride 7646-85-7 26-32 1 mg/m3 1 mg/m3
Rheology Agent 9016-45-9 25-35 10.0mg/m3 5.0mg/m3


Unlisted percentages are non-hazardous stabilizers, surfactants and water.
None of the materials in this product are listed in NTP, IARC, or OSHA as carcinogens.

Section 03 Physical Data
Melting Point N/A
Boiling Point N/A
Vapor Pressure N/A
Vapor Density ( air is 1) N/A
Solubility in Water 100%
Appearance & Color White paste
Specific Gravity 0.9
Odor None
% Volatile N/A
pH N/A
Evaporation Rate :(nBuAc=1) N/A
Section 04 Fire and Explosion Hazard Data
Flash Point None
Flammable Limits None
Extinguishing Media N/A
Fire Fighting Equipment Non-Flammable
Special Precautions None
Section 05 Reactivity Data
Stability Hazardous polymerization will not occur.
Conditions to Avoid Inhalation of fumes.
Incompatibility N/A
Hazardous Decomposition Products Hydrochloride fumes.
Section 06 Spill, Leak and Disposal Procedures
Action to take for spills/leaks Dilute with water.
Disposal method Dispose of per federal, state and local regulations.
Section 07 Health Hazard Data
Eye Irritation with possible corneal injury.
Skin Contact May cause skin irritation.
Skin Absorption Constant and continuous contact may cause
Irritation and acid burns.
Ingestion Slightly toxic. Do not induce vomiting, give
lots of milk or water. Contact a physician.
Inhalation Throat irritation may occur. Remove victim to fresh air.
Systemic & Other Effects Over exposure may cause irritation of mucous membranes.
Section 08 First Aid Procedures
Ventilation Local exhaust to remove acid fumes from breathing area.
Respiratory Protection Use NIOSH/OSHA approved respirator for
dust and acid fumes.
Eye Protection Safety goggles and/or full face shield in all splash conditions.
Skin Protection Use rubber gloves.
Other Follow all NIOSH/OSHS health guidelines for
chemical hazards.
Section 09 Special Handling Information
Ventilation Local exhaust to remove acid fumes from breathing area.
Respiratory Protection Use NIOSH/OSHA approved respirator for
dust and acid fumes.
Eye Protection Safety goggles and/or full face shield in all splash conditions.
Skin Protection Use rubber gloves.
Other Follow all NIOSH/OSHS health guidelines for
chemical hazards.
Section 10 Special Precautions and Additional Information
Storage Store in cool, dry, well ventilated area
Handling Information Avoid contact with skin or eyes when handling