Amerway, Inc.
                                                                                         Quality Through People and Technology

Amerway #100 Type "R" Non-Activated Rosin Flux


Material Safety Data Sheet

Section 01 Identification
Information furnished by: Amerway, Inc.
3701 Beale Avenue
Altoona, PA 16601
Date effective: 1/01/08
Emergency phone: 1-814-944-0200
Chemtrec: 1-800-424-9300
Product or trade name:

Amerway 100-15, Amerway 100-25

Amerway 100-35 Type “R” Non-Activated

Rosin Flux

Product Use: Soldering flux
Person to contact: Terry Buck
Section 02 Constituents      
Chem CAS %Wt. PEL/PPM TLV/PPM
2-Propanol 67-63-0 65-85 400 400

None of the materials in this product are listed in NTP, IARC, or OSHA as carcinogens.

Section 03 Physical Data
Melting Point N/A
Boiling Point 181 F
Vapor Pressure 31.2 mm Hg @ 20 C
Vapor Density ( air is 1) > 2
Solubility in Water 65-85 %
Appearance & Color Amber liquid with alcohol odor.
Specific Gravity 0.83, 0.86, 0.884
Odor Rubbing alcohol like odor.
% Volatile 65-85 %
pH N/A
Evaporation Rate :(nBuAc=1) 1.7
Section 04 Fire and Explosion Hazard Data
Flash Point / Method Used 58 F Seta Flash Closed Cup
Flammable Limits 2.0 Lower, 12.0 Upper
Extinguishing Media Apply foam, dry chemical, CO2, water.
Fire Fighting Equipment Use blanket effect to smother fire, use water only in fine mist spray. Firefighters should use respiratory protection for fumes and toxic degradation products.
Special Precautions N/A
Section 05 Reactivity Data
Stability Stable
Conditions to Avoid Open flame, ignition sources, strong oxidizers.
Hazardous Polymerization Will not occur.
Incompatibility Strong oxidizers.
Hazardous Decomposition Products

Oxides of carbon in fire conditions.

products in fire conditions.

Section 06 Spill, Leak and Disposal Procedures
Action to take for spills/leaks Soak up with absorbent, eliminate sources of
ignition. Remove residual with alkaline detergent.
Disposal method Incinerate or dispose of per federal, state or local regulations.
Section 07 Health Hazard Data
Eye Irritation with possible corneal injury.
Skin Contact Dehydration of the skin.
Skin Absorption Constant and continuous contact may cause irritation.
Ingestion Slightly toxic. Ingestion of a large quantity may cause drowsiness
and loss of consciousness. Stomach cramps, pain, nausea, vomiting
may occur.
Inhalation Headache or throat irritation may occur.
Systemic & Other Effects Overexposure may cause irritation of the mucous
membranes
Section 08 First Aid Procedures
Eyes Wash with water and seek medical attention.
Skin Wash with water, remove contaminated clothing, contact a physician if irritation occurs.
Ingestion If a large quantity is swallowed, give luke warm water (pint) if victim is conscious and alert. Do not induce vomiting. Risk of damage to lungs exceeds poisoning risk. Obtain emergency medical attention.
Inhalation Remove to fresh air. Seek medical attention if irritation persists.
Section 09 Special Handling Information
Ventilation Local exhaust to remove smoke / fumes from breathing area.
Respiratory Protection Typically, not required.
Eye Protection Safety glasses / goggles.
Skin Protection Rubber gloves preferable.
Other N/A
Section 10 Special Precautions and Additional Information
Storage Keep away from heat and open flames.
Handling Information Avoid contact with eyes.
 
      Website by Precision Business Solutions                                                                                                                                       © Amerway.com